[ Sprocess ] [ StructureEditor ] [ Sdevice ] [ Other TCADs ]
Synopsys Sentaurus TCAD
connect to the virtual machine
ssh -X user@cloud-gw-223.to.infn.it
The first time you start Sentaurus, you have to set the STDB environment variable.
1. CAD admin usually creates a DB folder for each user inside /data. If not, create a folder called DB inside your space on /data disk
DON'T put your DB folder inside /home, or the simulations will saturate the disk in a short time and TCAD will crash.
sudo mkdir /data/users/<your_name>/DB
2. edit your .cshrc file by typing (NOTE: by default, administrator sets cshell as default shell for users)
sentenv STDB = /data/users/<your_name>/DB
lauch Sentaurus Workbench by typing
swb
or Structure Editor
sde
!!!selinux disabled to let xauth work properly (configuration file edited)
Issues
- Simulation with correct syntax fails (red node color):
- saturated disk space
- you changed the command file between one node and the other
Request an account/report a problem
mail me cenna@NOSPAMto.infn.it
for hardware problems with the server, contact Centro di Calcolo
Running simulations/ CPU usage
When you run a simulation, you can specify the number of threads/cores which will be used. Our machine has 16 cores: usually, the programs accepts a number of threads <16.
Please don't use the “priority run” option, this will not speed up that much the simulation but will consume a lot of computing resources.
Where to learn Sentaurus
Europractice courses: http://www.europractice.stfc.ac.uk/training/
Basic tutorial by Synopsys: click on the “T” icon on Sentaurus Workbench